Construction and Design of Variac

Construction and Design of Variac

Project / Seminar Material
Reference ID: PS-24250-TM

DEDICATION

This research material titled “Construction and Design of Variac” is dedicated to God for his enabling grace, and to all computer enthusiasts who contributed to make life a pleasant experience during my research documentation.

ACKNOWLEDGEMENT

I extend my sincere gratitude to all those who contributed to the completion of this project. Special thanks to my Supervisor (Name of your Supervisor), the Head of Department (Name of your HOD), the Lecturers in the department of Electrical / Electronics Engineering (EE), Book Authors and Profound Scholars of existing or related project material on “Construction and Design of Variac” for their invaluable guidance, support, and expertise throughout the journey.

I am also grateful to your study area (mention any funding organizations, if applicable) for their financial assistance. This research would not have been possible without the encouragement and assistance of some stakeholders (mention any mentors, teachers, or colleagues). Additionally, I would like to acknowledge the understanding and patience of my family and friends during this endeavor. Your unwavering support has been a constant source of motivation. Thank you all for being part of this meaningful endeavor.

ABSTRACT

Variac is a single primary winding wrapped around a magnetic core is used as in the autotransformer but instead of being fixed at some point, the secondary is tapped continuously over the output voltage range. The aim of the study is to design and construct a 2kva (0v - 240v) range, with a step up of 20v at 10 step. In achieving this aim, the following specific objectives were set out as follows to: power the electrical/electronic and laboratory equipments with a fixed input voltage, design a system that will be able to vary voltage from 0V to 240V, construct the system stated in the aim above using locally available materials, and examine the design process of 2kva autotransformer with a step up of 20v at 10 step. All the details that are required to help in constructing the variac to ensure that it gives the desired results were also determined. The appropriate insulation materials as well as the electrical accessories were selected taking the power, voltage and current rating of the variac into consideration. The construction was divided into three segments: magnetic circuit, electrical circuit and casing construction. The magnetic circuit construction gives details of the magnetic core and how it was prepared for winding along. The electrical circuit construction gives details of the whole winding along with insulation and leads termination. The constructed work was tested. The tests carried out include continuity test, insulation resistance test, mechanical and running tests. This study will be of immense benefit to other researchers who intend to know more on this study and can also be used by non-researchers to build more on their research work. This study contributes to knowledge and could serve as a guide for other study.


Construction and Design of Variac

CHAPTER ONE

1.1 Introduction

A variac is also known as a variable autotransformer, which is a single primary winding wrapped around a magnetic core is used as in the autotransformer but instead of being fixed at some point, the secondary is tapped continuously over the output voltage range. In the construction, a toroidal core was used so as to allow for easy variation of output voltage. All the details that are required to help in constructing the variac to ensure that it gives the desired results were also determined. The appropriate insulation materials as well as the electrical accessories were selected taking the power, voltage and current rating of the variac into consideration. The construction was divided into three segments: magnetic circuit, electrical circuit and casing construction. The magnetic circuit construction gives details of the magnetic core and how it was prepared for winding along. The electrical circuit construction gives details of the whole winding along with insulation and leads termination. The constructed work was tested. The tests carried out include continuity test, insulation resistance test, mechanical and running tests.

As a prelude to other parts of this study, this chapter will discuss the background upon which this study was initiated, the statement of problems that led to this study, the Aim and Objectives of the study. Others are Significance of the study, Scope of work, Limitations of the Study and Definition of technical terms.


1.2 Background of Study

In the 1880s, Around 50 years before that in 1830 property of induction which is the working principle of transformer was discovered. Later the transformer design was improved resulting in more efficiency and lesser size. Gradually the large capacity of transformers in the range of several KVA, MVA came into existence. In the year 1950, 400KV electrical power transformer was introduced in high voltage electrical power system. In the early 1970s, unit Rating as large as 1100 MVA was produced and 800KV and even higher KV class transformers were manufactured in year of 1980.

Electric power is the backbone of modern industrial society. Electricity extraordinary versatility means it can be put in almost limitless set of applications which include transportation, heating and communications etc. Electricity is usually generated, transmitted before it is distributed to the final consumer. During this process, voltage generated is transformed from one level to another with the aid of a transformer. The transformer which transforms the voltage has been proved to be the easiest means through which voltage can be transformed from one level to another. Without transformers the electrical energy generated at generating stations won’t probably be sufficient enough to power up a city. In cases where there are no transformers, the number of power plants needed to be set up in order to power up a city will be so numerous. It is expensive. Numerous power plants have to be set up in order to have sufficient power. Transformers help by amplifying the Transformer output (stepping up or down the level of voltage or current). When the number of turns of the secondary coil is greater than that of primary coil, such a transformer is known as step up transformer. Likewise when the number of turns of coil of primary coil is greater than that of secondary transformer, such a transformer is known as step down transformer.

A transformer therefore, is a static machine used for transforming power from one circuit to another without changing frequency. Since there is no rotating or moving part so transformer is a static device. It is usually made up of two winding called the primary winding (input) and the secondary winding (output). Transformer works on the principle of mutual induction. It operates on AC supply. The ability of the transformer to be able to transform voltage from one level to another means it can serve different classes of consumers.

Unlike the previous voltage transformer which have two electrically isolated windings called: the primary and the secondary, An autotransformer is an electrical transformer which has only one single voltage winding which is common to both sides i.e. The primary and the secondary winding are linked together both electrically and magnetically. The winding has at least three terminals. i.e. it consists of a single copper wire, which is common in both primary as well as secondary circuit. The copper wire is wound a laminated silicon steel core, with at least three tapings taken out. The Secondary and primary circuit share the same neutral point of the winding.

The VARIAC to be constructed is a special type of transformer. It has become generic and commonly referred to as any variable autotransformer. It is called variable autotransformer because they have the same as that of autotransformer but the autotransformer has a fixed and tapped secondary that produces a voltage output at a specific level while the variable autotransformer is designed such that it can be varied continuously over the entire voltage range for which it is designed.

Therefore, in Nigeria where the research was carried out, the activities that was conducted is to know the Construction of variac (0v-240v) Range.


1.3 Aim and Objectives of Study

The aim of the study is to design and construct a 2kva (0v - 240v) range, with a step up of 20v at 10 step. In achieving this aim, the following specific objectives were set out as follows:

  1. To power the electrical/electronic and laboratory equipments with a fixed input voltage
  2. To design a system that will be able to vary voltage from 0V to 240V
  3. To construct the system stated in the aim above using locally available materials.
  4. To examine the design process of 2kva autotransformer with a step up of 20v at 10 step.

1.4 Scope of Study

The study focuses on the design and construction of variac (0v - 240v) range with a step up of 20v at 10 step.


1.5 Limitations of the Study

During the course of this study, many things militated against its completion, some of which are:

  1. Time Constraint: The time frame given to accomplish this project was very short due to school academic calendar and it was carried out under pressure which made the researcher not to implement some necessary features.
  2. Research material: availability of research material is a major setback to the scope of the study.
  3. Frequent power failure: This made the researcher append more money on fuel to ensure sustainable power.
  4. Financial Constraint: Insufficient fund tends to impede the efficiency of the researcher in sourcing for the relevant materials.

1.6 Significance of Study

This study will be of immense benefit to other researchers who intend to know more on this study and can also be used by non-researchers to build more on their research work. This study contributes to knowledge and could serve as a guide for other study.

CHAPTER TWO

2.0 Literature Review

2.1 Introduction

This chapter focuses on the review of related literature. A literature review includes the current knowledge as well as theoretical and methodological contributions to a particular topic. It documents the state of the art with respect to the topic you are writing. It surveys the literature in the topic selected. In this research work the literature review includes the …