Energy Optimization At GSM Base Station Sites Located in Rural Areas

Energy Optimization At GSM Base Station Sites Located in Rural Areas

@SparklynServices
WhatsApp Channel

DEDICATION

This research material, titled “Energy Optimization At GSM Base Station Sites Located in Rural Areas” is dedicated to God for His boundless grace and guidance. It is also a tribute to all computer enthusiasts whose contributions made my research journey smoother and enriched my documentation process, making the experience truly fulfilling.




ACKNOWLEDGEMENT

I am profoundly grateful to everyone who contributed to the successful completion of this project. I am especially grateful to my Supervisor (Name), the Head of Department (Name), and the Lecturers in the Department of Electrical / Electronics Engineering (EE) for their invaluable guidance and support. I also acknowledge the contributions of authors and scholars whose works on Energy Optimization At GSM Base Station Sites Located in Rural Areas provided essential insights. Special thanks go to my study area (and any funding organizations, if applicable) for their financial assistance. I am equally thankful to stakeholders, including mentors, teachers, and colleagues, for their encouragement and support. Finally, I deeply appreciate my family and friends for their patience and unwavering support throughout this journey. Your contributions have been instrumental in making this research a reality.




ABSTRACT

The work presented in this thesis explored the potential of using a mix of renewable energy resources (hybrid power systems, HPSs) to generate electricity that meets power needs of mobile base stations at rural areas in Nigeria. The study was based on theoretical mathematical modeling and simulation using the hybrid optimization model for electric renewables (HOMER) software. A sample of eight hypothetical off-grid remote telecommunication base station (BTS) sites at various geographical locations in Nigeria was used for the study.

These locations include: Abaji (Abuja, FCT), Nkanu-West (Enugu), Ikwerre (Rivers), Nembe (Bayelsa), Mopa-Muro (Kogi), Kauru (Kaduna), Guzamala (Borno), and Tureta (Sokoto), and were selected to reflect the various climatic conditions in Nigeria. Eight different combinations (HPS options) of four energy resources [small-hydro power (SHP), wind turbine generator, solar photovoltaic (SPV) and diesel generator (DG)] were studied and compared for each of the eight selected BTS sites. These are: Hybrid (Solar, Wind & Hydro) + DG; Hybrid (Solar & Hydro) + DG; Hybrid (Wind & Hydro) + DG; Hydro only + DG; Hybrid (Solar & Wind) + DG; Solar only + DG; Wind only + DG. Total Net Present Cost (NPC) and total CO2 generated are used as indices for measuring the optimization level of each energy solution, and the option with the highest optimization value is considered to be the best energy solution for that base station site.

The quantitative results of the study (as reported here) show that the hybrid power system can be more cost-effective and environmentally friendly in providing energy to BTS sites than diesel generators. The results also show that there is no general least-cost option for powering GSM base station sites at different locations. It all depends on climatic conditions and available renewable energy resources.

A major contribution of this work is the demonstration (by these results) that it is possible to develop an optimized energy map for appropriate locations of GSM Base Station sites in Nigeria, both as a design guide for network operators and for the formulation of energy use policies by the national telecommunications regulatory authority (the NCC). One of such policies could be the requirement that any network operator intending to site a base station in any location should first produce an optimized energy feasibility study of the location before an approval would be granted.



Energy Optimization At GSM Base Station Sites Located in Rural Areas


1.0 Introduction

Communication services have faced several challenges with the increasing spread of wireless voice and data signals into remote areas [1]. Power supply is one of the critical challenges the telecommunication operators confront in deploying their networks. This challenge is readily overcome in the developed countries as a result of well-developed power infrastructure. in the developing world, where national electricity grid exists, it is always the energy solution of choice for powering Base Transceiver Stations (BTSs).

Unfortunately, it is not always reliable and has limited coverage. This is complicated in developing countries like Nigeria as mobile communication extends more and more into rural areas outside the reach of national grid. The electrification by grid extension or secondary power station can only reach a small minority of the population in rural areas. In view of the dispersion of localities, the cost of production, transmission and especially distribution of electricity, would be expensive.


CHAPTER TWO

2.0 Literature Review

2.1 Introduction

This chapter focuses on the review of related literature. A literature review includes the current knowledge as well as theoretical and methodological contributions to a particular topic. It documents the state of the art with respect to the topic you are writing. It surveys the literature in the topic selected. In this research work the literature review includes the conceputal review, theoretical framework, the review of related literature …

Procedure for Accessing and Downloading the Complete Material in PDF or DOCX Format

Above is a preview excerpt of the full study on “Energy Optimization At GSM Base Station Sites Located in Rural Areas”. The complete material, including all five chapters, is available for download upon request.


To obtain the complete research material content, simply place an order by paying the specified project or seminar fee using the account details or electronic payment (E-payment) system provided below.


Seminar Material
₦3,000
Project Material
₦5,000

For Mobile Money (MoMo) and Researchers Outside Nigeria, Kindly Request Complete Material via WhatsApp.


Account Details - For USSD / POS Transfer

ACCT NAMESPARKLYN SERVICES
Zenith Bank PLC1222599051
MoniePoint (MFB)8030511988
Paycom (OPay)8030511988

–– or ––



After payment, send message containing your payment receipt to Sparklyn Services with the phone number displayed below.


Once payment is confirmed, the complete document will be delivered via WhatsApp or email in Microsoft Word (MS-Word) format.




You can get more research topics on Electrical / Electronics Engineering, if you did not see your preferred topic from the alternate list above.

Defense Procedure for Electrical / Electronics Engineering Researchers


In preparation for defending a project or seminar on Energy Optimization At GSM Base Station Sites Located in Rural Areas, it is imperative that as a nursing student, you demonstrate comprehensive knowledge of your research. The defense process is structured to include presenting your work, answering questions, and illustrating its pertinence. Initially, provide a succinct yet thorough introduction to your research topic, emphasizing its importance and the objectives, ensuring that both the audience and the External Examiner can understand the scope of your study.


Prior to your defense, be thoroughly acquainted with your research abstract and the critical elements of Chapter One, including motivation for embarking on this research, problem statement, objectives, and significance. In Chapter Two, be ready to cite at least two references from the literature review. For Chapter Three, you should be equipped to discuss the methodologies, tools, and techniques utilized. In Chapter Four, defend your research by justifying the findings and linking them to your research objectives.


Conclude your defense by succinctly summarizing the study and offering insightful, evidence-based recommendations. A professional dress code, such as wearing a suit and tie, is vital to create a favorable impression and elevate your presentation.


During the question and answer segment, the External Examiner may pose questions pertaining to your research. If confronted with a challenging or irrelevant question, respond diplomatically with, “Sorry, Sir/Madam, the question asked is beyond the scope of my study.” Whenever possible, direct your answers back to your research findings to reinforce your expertise.


Page Content Headings - Energy Optimization At GSM Base Station Sites Located in Rural Areas

    Download Material (Docx)